A simple low-cost solution that uses existing
thermostat wiring and provides comfort upstairs and downstairs without using zoning.
Reduces wiring by about 40%
Eliminates bypass damper and ductwork.
No transformer to install & wire.
42 to 57% savings in purchased materials compared to traditional zoning.
No DAT sensor to install & wire.
Material Savings
No zoning panel to install & wire.
Labor Savings
Reduces HERS zoning testing.
How It Works
Contractor Resources
Click on the Resources link for contractor resources including videos, manuals, brochures and other materials for all Comfort365 products.
Add On / Replacement
Where To Buy
Click on the Distributor link to find a distributor in your area. If there is not a distributor in your area, please contact us.
Comfort365 Wiring Hub Solution
Features
Easily Upgrade to WiFi
The Comfort365 can easily be upgraded to WiFi to provide homeowners with remote access to their home's heating and cooling system. The Comfort365 WiFi version simply
Nighttime Energy Savings
The Comfort365 includes Energy Star nighttime setback temperatures. For additional savings, homeowners can take advantage of the Nighttime Airflow option which uses the temperature sensor in the bedroom area to control heating
Meets Title 24
The Comfort365 has no effect on the HVAC equipment. The equipment operates at its rated airflow and return temperature.
and cooling calls and direct more airflow to the bedroom area at night and less airflow to the unoccupied living area.
plugs into the same subbase - no additional wiring needed. Also, only one Comfort365 WiFi thermostat is required compared to zoning which requires purchasing two WiFi thermostats.
Modern Touchscreen Thermostat
Homeowners will appreciate the modern, touch screen thermostat with high definition LCD display compared to the outdated, non-touch builder grade thermostats used in conventional zoning with small LCD displays.
Programmable Communicating Thermostats
Temperature Sensors
Damper
R80CJXX Upstairs
Modulating Damper
R80CJXX Downstairs
Modulating Damper
TS5WL Wireless Upstairs
Temperature Sensor
(1 or 2 sensors can be used)
C365C32 or C365C32WF Comfort365
Programmable Thermostat
HVAC
Equipment
C365C32
C365C32WF
Use with Wiring Hub. All equipment.
Use with Wiring Hub. All equipment. WiFi Enabled.
TS510W
TS520W
R80CJXX
Wired temperature sensor for single sensor installations.
Wired temperature sensor for two sensor installations.
Damper, Plug & Play with XX diameter from 6 to 20 inches.
URCXX
Damper, XX diameter from 6 to 20 inches. Actuator sold separately.
A80MJ
Actuator, Modulating, Plug & Play, 24VAC, 2.4VA.
Thermostat uses existing wiring to the equipment.
Dampers plug into the Wiring Hub.
No wireless adapter to install & wire.
A common problem found in two-story homes is the uneven heating and cooling of the upstairs and downstairs. During the summer, the upstairs is too warm. During the winter, the downstairs is too cool. The Comfort365 solves the problem by dynamically adjusting the airflow based on the upstairs and downstairs temperatures.
A Comfort365 thermostat is installed in the living space, a wireless temperature sensor is installed in the bedroom space, modulating dampers are installed to control the airflow to the living space and the bedroom space and the Wiring Hub is installed at the equipment.
Every 2 minutes during heating and cooling calls, the C365 thermostat compares the temperature at the sensor and the temperature at the thermostat. If the temperatures are different, the Comfort365 automatically adjusts the modulating dampers 2% so that more airflow is directed to the space that needs it for a uniformly comfortable home.
eLink Radio Simplifies Installation
The ELR1 Radio Module plugs into the Wiring Hub and eliminates having to install new wiring between the Wiring Hub and the upstairs wireless sensor.
Comfort365 Wiring Hub
WH11
WH32
Use with GE equipment, 1H/1C.
Use with GE, conventional and dual fuel heat pump equipment, 3H/2C.
TS5WL
Wireless temperature sensor for single or dual sensor installations. Requires ELR1.
Plug In Radio Module
ELR1
Plug-in radio module. Required when using wireless sensor.
TS3
Outdoor air temperature sensor. Required when using dual fuel heat pump equipment.
WH11 or WH32
Wiring Hub
Wiring Hub solution using wireless upstairs temperature sensor
Number of wires
Plug and Play
Wiring Hub solution using wired upstairs temperature sensor
Existing
Home
Wiring
R80CJXX Upstairs
Modulating Damper
R80CJXX Downstairs
Modulating Damper
(1) TS510W or (2) TS520W Wired
Upstairs Temperature Sensor
C365C32 or C365C32WF Comfort365
Programmable Thermostat
HVAC
Equipment
WH11 or WH32
Wiring Hub
Number of wires
Plug and Play
Existing
Home
Wiring
(949) 916-0945
Contractor
Builder
Homeowner
26072 Merit Circle #110 / Laguna Hills, CA 92653 / 949-916-0945 / Fax 949-458-8502
eControls
Copyright 2017
Home
Comfort365 for New Construction
Comfort365 for Add On/Replacement
Direct Airflow Controls
ProZone Zoning
One Zone Controls
Fresh Air Controllers
Products
About Us
Contact Us
Videos
Comfort365
Direct Airflow Controls
ProZone Zoning
One Zone Controls
Fresh Air Controllers
Resources